Test Equipment Depot - 800.517.8431

View Shopping Cart | My Account

 

Free Ground Shipping for Orders over $100

Used Test Equipment
Completely refurbished,
aligned & calibrated to original
manufacturers' specifications
Used Equipment Catalog
<< Used Time Domain Reflectometers (TDRs)
<< Tektronix Used Test Equipment Price List

Tektronix 1502C/1503C
Metallic Cable Testers, Refurbished

  • Distance to faults
  • Cable Propagation velocity
  • Loss and load mismatch
  • Quantification of damage from opens, shorts, frays, crimps and water
  • Faulty taps and unterminated lines in LAN and CATV environments
  • Stripline and Cable Impedance
  • Characterizing LAN installations

Options:

  • 03-Internal Battery
  • 04-YT-1 Chart Recorder
  • 05-Metric Version
  • 06-Ethernet Testing (1503 only)
  • 08-Token Ring Adapter
  • 09-USOC Adapter (1503 only)
  • 10-Token Ring Interface


Click here for a larger image of the 1503cClick here for larger image
Tektronix 1503C Shown
 
Product Information
Common
Characteristics
HTML
TDR Characteristics HTML
Ordering Info Jump to Product Models, Prices, Accessories, and Ordering Information

 

The portable, rugged 1502C and 1503C TDR Cable Testers are portable maintenance tools that are simple to operate and will test most dual conductor metallic cables under virtually any condition.  A high-contrast LCD, waveform storage, and PC controllability make the 1502C and 1503C TDRs well-suited for a wide range of testing applications.  The 1500C Series uses TDR to identify and locate cable faults.  When the instrument is connected to the line to be tested it sends out electrical pulses that are reflected back to the tester by impedance changes in the cable as a function of distance.  Moving the cursor to the displayed fault produces an onscreen readout of distance to the fault.

1502C High Resolution MDTR

The 1502C transmits 200 ps rise time step pulses down the cable under test.  The reflected energy is displayed on the LCD and the user can then determine the type of fault.  When testing 50 ohm cable with a velocity of propagation equal to 0.66, the 1502C Metallic TDR allows the determination of 0.5 ohm cable faults.  Multiple faults as close together as 0.6 inches can be resolved.
The 1502C has a menu selectable ohms-at-cursor function that allows direct readout of impedances.  The 1502C is matched to 50 ohm cables, but may be used on others by adjusting the front panel vertical scale control or using optional impedance adapters.
The 1502C has a maximum range of 2000 feet and is the best MTDR for high resolution fault location on short lengths of cable.

1503C General Purpose MDTR

The 1503C MTDR generates high-energy, 1/2-sine shaped pulses for testing long cable runs.  The 1503C has 2, 10, 100 and 1000 nanosecond pulse widths.  Use of the 2 ns pulse width permits determination of multiple faults as close together as one foot.  Cable impedances of 50, 75, 93, and 125 ohms are selectable at the front panel.  The 1503C is input protected to 400 volts.
The 1503C has a range of up to 50,000 feet and is the best metallic TDR for general purpose applications.

1503C Option 06 for Ethernet Testing

The 1503C with Option 06 allows TDR testing of an active Ethernet bus.  Tests are provided for detecting transceivers that ignore the collusion signal (babbling transceivers) and transceivers that ignore the carrier signal.

Menu Selections

The 1502C and 1503C offer menus to access a variety of parameters and information.  The main menu gives you access to Help Screens; Velocity of Propagation Values; Impedances of Different Cables; Instrument/Front Panel Configurations; and Instrument Diagnostics.

YT-1 Chart Recorder

For permanent records of cable tests, the Option 04 (YT-1) chart recorder is available for both the 1502C and 1503C.


top >
 
 

TDR Characteristics

  1502C 1503C
Test Signal Step rise 1/2 sine
Amplitude 300 mV nominal into 50 W load 2.5 V Terminated
5.0 V Unterminated
System Risetime 10%-90% 200 ps (1.15 in./2.92 cm)  
Pulsewidths   2 nsec, 10 nsec, 100 nsec, 1000 nsec
Output Impedance 50Ω 50Ω, 75Ω, 93Ω, 125Ω
Electrostatic Discharge Protection 1 Kv/500 pF capacitor/1 K resistor  
Input Protection ± 1 amp (DC) ± 400 V (DC + peak AC) to a maximum of 440 Hz
Maximum Range 2,000 ft/625 meters 50,000 feet/15,000 meters
Distance Readout Resolution 0.05 inch/0.12 cm 0.04 ft/0.01 m
Noise Filtering 1 to 128 averages 1 to 128 averages
Vertical Scale 0.5 mr/div to 500 mr/div 0 dB to 63.75 dB gain
Vertical Accuracy ± 3% of full scale ± 3% of full scale
Dist/Div 0.1 to 200 ft/div; 0.025 to 50 m/div 1 to 5000 ft/div; .25 to 1000 m/div
Horizontal Accuracy 1.6 inches (.041 m) or ± 1% of measured distance, whichever is greater at Vp = 0.66 2% ± 0.02 feet of measured distance plus uncertainty in Vp

top >
 
Common Characteristics: 1502C and 1503C
Environmental Characteristics Meets capabilities of a Type III, Class 3, Style C instrument (except EMI where it meets FCC: Part 15, 3, A, and VDE: 0871, Class B) as prescribed by MIL-T-28800C
Power Requirements
AC Power Line Voltage: 115 V AC (90 to 132 V AC) and 230 V AC (180 to 250 V AC)
Line Frequency: 45 to 440 Hz
DC Power Battery Operation (Option 03): At least 8 hours (15 to 25C charge and discharge temperature), including 30 chart recordings
Full Charge Time 20 hours maximum
Physical Characteristics
Width 315 mm (12.4 in)
Height 127 mm (5.0 in)
Depth 475 mm (18.7 in)
Net Weight, without front cover or accessories 7.3 kg (15 lb)

top >
 
Ordering Information
Model

Description

Price
1502C Metallic TDR Cable Tester Please Call
1503C Metallic TDR Cable Tester Please Call

top >
 
 

Used Equipment Catalog

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved