<< Tektronix 2335 Product PageTektronix 2335
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| CHARACTERISTICS | |||
| Bandwidth*1 and Risetime | -15°C to +40°C | +40°C to +55°C | |
| Dc to at least 100 MHz, 3.5 ns | Dc to at least 85 MHz, 4.15 ns | ||
| *1 Measured at -3 dB point at all deflection factors from a 50-Ω source terminated in 50Ω. Bandwidth may be limited to 20 MHz by bandwidth limit switch. | |||
| Lower -3 dB Point (AC Coupling) 1X Probe | 10 Hz or less; 10X Probe: 1 Hz or less | ||
| Deflection Factor | 5 mV/div to 5 V/div. 1-2-5 sequence, accurate ± 3%. Uncalibrated, continuously variable between steps and to at least 2 mV/div. | ||
| Display Modes | CH1, CH2, Add CH2 (normal and inverted), alternate, chopped (275 kHz rate). | ||
| Common-Mode Rejection Ratio | At least 10:1 at 50 MHz for common-mode signals of 6 div or less. | ||
| Input R and C | 1 MΩ ±2% paralleled by 20 pF ± 10% | ||
| Maximum Input Voltage | Ac or dc coupled, 400 V (dc + peak ac) or 500 V p-p ac at 1 kHz or less. | ||
| HORIZONTAL DEFLECTION | |||
| Time Base A | 0.05 µs/div to 0.5 s/div (1-2-5 sequence). X10 magnified extends maximum sweep rate to 5 ns/div. | ||
| Time Base B | 0.05 µs/div to 50 ms/div (1-2-5 sequence). X10 magnified extends maximum sweep rate to 5 ns/div. | ||
| Variable Time Control | Time base A provides continuously variable uncalibrated sweep rates between steps and to at least 1.25 s/div. | ||
| Time Base A and B Accuracy*1 | +20°C to +30°C | -15°C to +55°C | |
| Unmagnified | ± 2% | ± 3% | |
| Magnified | ± 3% | ± 4% | |
| *1 Full 10 divisions. | |||
| Display Modes | A, A intensified by B, B delayed. | ||
| CALIBRATED SWEEP DISPLAY | |||
| Delay Time Range | Continuous from 50 ns to at least 5 s after start of delaying sweep. | ||
| Differential Time Measurement Accuracy | +15°C to +35°C |
-15°C to +55°C | |
| 0.75% + 0.015 major dial div | 1.5% + 0.015 major dial div | ||
| Jitter | 1 part or less in 20,000 (0.005%) of 10 times the A Sweep Time/Div setting. | ||
| TRIGGERING | |||
| A Trigger Mode | Normal (sweep runs when triggered). Automatic (sweep free runs in absence of a triggering signal and for signals below 30 Hz). Single sweep (sweep runs once on first triggering event after reset selector is pressed). LED indicates when sweep is triggered and when single sweep is ready. | ||
| Sensitivity and Coupling | Coupling | To 25 MHz | At 100 MHz |
| Dc Internal | 0.3 div deflection | 1.5 div deflection | |
| Dc External | 50 mV | 150 mV | |
| Dc External divided by 10 | 500 mV | 1.5 V | |
| Ac | Requirements increase below 60 Hz | ||
| Ac LF Reject | Requirements increase below 50 kHz | ||
| Ac HF Reject | Requirements increase above 50 kHz | ||
| A Trigger Hold Off | Adjustable control permits a stable presentation of repetitive waveforms. | ||
| Runs After Delay | B Sweep starts immediately after the delay time selected by the Delay Time Position control and is independent of B trigger signal. | ||
| Triggerable After Adjustable Delay Time | The B sweep trigger is sourced from a composite of CH1 and CH2; CH1 only, 2 only or from the Ext Trigger input connector. | ||
| Jitter | 1.0 ns or less at 100 MHz and 5 ns/div. | ||
| A Trigger View | A spring loaded pushbutton overrides other vertical controls to display the signal used to trigger the A Sweep. This control provides quick verification of the (trigger) signal and permits a time comparison between the vertical input signal and the trigger signal. Deflection factor is 100 mV/div ± 40% (1 V/div with Ext divided by 10). | ||
| Level and Slope | Internal, permits selection of triggering at any point on positive or negative slope of vertical input signal. Level adjustment through at least ± 1 V in Ext, through at least ± 10 V in Ext divided by 10. | ||
| A Sources | Vertical Mode, CH1, CH2, Line, Ext, Ext divided by 10. | ||
| External Inputs | R and C 1 MΩ ± 10%, 20 pF ± 30%. 400 V (dc + peak ac) or 500 V ac p-p at 1 kHz or less. | ||
| X-Y OPERATION | |||
| Full Sensitivity X-Y (CH1 Horizontal, CH2 Vertical) | 5 mV/div to 5 V/div (1-2-5 sequence), accurate ± 5% from 0°C to +40°C, accurate ± 8% from -15°C to +55°C. X-axis bandwidth is dc to at least 2 MHz. Y-axis bandwidth is dc to at least 100 MHz. Phase difference between amplifiers is 3° or less from dc to 200 kHz. | ||
| DISPLAY | |||
| CRT | 8 X 10 div (8 mm/div) display. Horizontal and vertical centerlines further marked in 0.2 div increments. GH (P31) Phosphor standard. 18 kV accelerating potential. | ||
| Graticule | Internal, nonparallax, nonilluminated; markings for measurement of risetime. | ||
| Beam Finder | Compresses trace to within graticule area to locate an off screen signal. | ||
| Z-Axis Input | Positive-going, dc coupled signal decreases intensity; 5 V p-p signal causes noticeable modulation at normal intensity; dc to 20 MHz. | ||
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved