<< HP 8591A, 8593A, 8594A, 8595A
Product PageHewlett Packard
8591A, 8593A, 8594A, & 8595A
|
| HP 8591A SPECIFICATIONS | ||
| GENERAL | ||
| Temperature | 0° to +55°C operating; -40° to 75° C storage | |
| EMI compatibility | CISPR Pub. 11 and FTZ 526/527/79 | |
| Audible noise | < 37.5 dBA pressure and < 5.0 Bels power (IS0DP7779) | |
| Power requirements | 86 to 127 or 195 to 250 Vrms, 47 to 66 Hz. 103 to 126 Vrms, 400 Hz ± 10% | |
| Power consumption | < 300 VA; < 100 watts | |
| Frequency | ||
| Range | 9 kHz to 1.8 GHz (50 Ω); 1 MHz to 1.8 GHz (75 Ω, opt. 001) | |
| Reference | ||
| Aging | ± 2 X 10 -6/year | |
| Settability | ± 1 X 10 -8 | |
| Precision frequency reference (option 004) | ||
| Aging | ±2 X 10 -7/year | |
| Settability | ± 1 X 10 -8 | |
| FREQUENCY | ||
| Frequency readout accuracy (start, stop, center, frequency) | ||
| Span ± 10 MHz | ± (freq readout X freq ref error + 3% of span + 20% of RBW + 100 Hz) | |
| Span ± 10 MHz | ± (freq readout X freq ref error + 3% of span + 20% of RBW + 100 Hz) | |
| Marker count accuracy (signal to noise ratio ± 25 dB, RBW/span ± 0.01) | ||
| Frequency span < 10 MHz | ± (marker freq X freq ref error + counter res + 100 Hz) | |
| Frequency span > 10 MHz | ± (marker freq X freq ref error + counter res + 1 kHz) | |
| Counter resolution | selectable from 10 Hz to 100 kHz | |
| Frequency span | ||
| Range | 0 Hz (zero span), 10 kHz to 1.8 GHz | |
| Accuracy | ± 2% of span, span ± 10 MHz, ± 3% of span, span > 10 MHz | |
| Sweep time | ||
| Range | 20 ms to 100 s, span = 0 Hz or > 10 kHz; 20 µs to 100 s, span = 0 Hz (option 101) | |
| Accuracy | ± 3%, 20 ms to 100 s; ± 2% 20 µs to <20 ms (opt 101) | |
| Sweep trigger | free run, single, line, video, external | |
| Stability | ||
| Noise sidebands | ± 90 dBc/Hz at > 10 kHz offset from CW signal (1 kHz RBW, 30 Hz VBW, sample detector); ± 100 dBc/Hz at > 30 kHz offset from CW signal (1 kHz RBW, 30 Hz VBW, sample detector) | |
| Residual FM | < 250 Hz p-p in 100 ms (1 kHz RBW, 1 kHz VBW) | |
| System-related sidebands | <-65 dBc at > 30 kHz offset from CW | |
| AMPLITUDE | ||
| Amplitude range | -115 to +30 dBm (50 ohm); -63 to +75 dBmV (75 ohm, opt 001) | |
| MAXIMUM SAFE INPUT | 50 ohm | 75 ohm |
| Average cont power | +30 dBm (1 watt) | +75 dBmV (0.4 watts) |
| Peak pulse power | +30 dBm (1 watt) | +75 dBmV (0.4 watts) |
| dc | 25 Vdc | 100 Vdc |
| Gain compression, >10 MHz | ± 0.5 dB, total power at input mixer = -10 dBm | |
| Displayed average noise level | 115 to 113 dBm | |
| NOISE LEVEL | ||
| Spurious responses | ||
| Second harmonic distortion | 5 MHz to 1.8 GHz, < -70 dBc for -45 dBm tone at input mixer | |
| Third-order intermodulation distortion | 5 MHz to 1.8 GHz, <-70 dBc for two -30 dBm tones at input mixer and > 50 kHz sep | |
| Other input-related spurious | < -65 dBc for 30 kHz offset from CW signal | |
| Residual responses (input terminated and 0 dB attenuation) | ||
| 150 kHz to 1 MHz | < -90 dBm, 50 ohm | |
| 1 MHz to 1.8 GHz | < -90 dBm, 50 ohm; < -38 dBmV, 75 ohm | |
| Display range | ||
| Log scale | 0 to -70 dB from ref lev is cal'd; 1 to 20 dB/div in 1 dB steps; 8 divisions displayed | |
| Linear scale | 8 divisions | |
| Scale units | dBmV, dBmicroV, volts, watts | |
| Marker readout resolution | 0.05 dB, log scale; 0.07% of reference level, linear scale | |
| Fast sweep times for zero span (opt 101) | 20 µs to 20 ms, 0.7% of ref level for linear scale | |
| Reference level | ||
| Range | -115 to +30 dBm (50 ohm), -63 to +75 dBmV (75 ohm) | |
| Resolution | 0.01 dB for log scale; 0.12% of ref level for linear scale | |
| Accuracy, referred to -20 dBm ref level | 0 dBm to -59.9 dBm, ± (0.5 dB + input atten acc @ 50 MHz); -60 dBm to -115 dBm, ± (1.25 dB +input atten acc @ 50 MHz) | |
| Frequency response | ||
| Absolute | ± 1.5 dB, referred to 300 MHz CAL OUT | |
| Relative flatness | ± 1.0 dB, referred to midpoint between highest and lowest response deviations | |
| Calibrator output | ||
| Frequency | 300 MHz ± (300 MHz X freq ref error) | |
| Amplitude | -20 dBm ± 0.4 dB (50 Ω); +28.75 dBmV ± 0.4 dB (75 Ω, opt 001) | |
| Input attenuator | ||
| Range | 0 to 60 dB in 10 dB steps | |
| Accuracy at 50 MHz, 10 dB atten | ± 0.5 dB, 0 to 50 dB; ± 0.75 dB, 60 dB | |
| Resolution bandwidth | 1 kHz to 3 MHz, ± 20% | |
| Switching uncertainty, ref to 3 kHz bandwidth | 3 kHz to 3 MHz RBW, ± 0.4 dB; 1 kHz, ± 0.5 dB | |
| Video bandwidth range | 30 Hz to 1 MHz | |
| Log to linear switching | ± 0.25 dB at reference level | |
| Display scale fidelity | ||
| Log incremental accuracy | ± 0.2 dB/2 dB, 0 to -70 dB from ref lev | |
| Log maximum cumulative | ± 0.75 dB, 0 to -60 dB from ref level; ± 1.0 dB, 0 to -70 dB from ref level | |
| Linear accuracy | ± 3% of reference level | |
| HP 8593A SPECIFICATIONS | |
| FREQUENCY | |
| Frequency range | 9 kHz to 22 GHz; 9 kHz to 26.5 GHz (option 026) |
| Frequency reference | |
| Aging | ± 2 X 10 -6/year |
| Settability | ± 5 X 10-7 |
| Temperature stability | ± 5 X 10-6 |
| Precision frequency reference (Opt 004) | |
| Aging | ± 1 X 10-7/year |
| Settability | ± 5 X 10-8 |
| Temperature stability | ± 1 X 10-8 |
| Frequency readout accuracy | ± (frequency readout X frequency reference error + 3% of span + 20% of RBW + 100 Hz sweep time) for spans ± 10 MHz; ± (freq readout X freq ref error + 3% of span + 20% of RBW) for spans > 10 MHz |
| Marker count accuracy (signal-to-noise ratio)± 25 dB, RBW/span ±0.01 | ± (marker freq X freq ref error + counter res + 100 Hz) spans ± 10 MHz; ± (marker freq X freq ref error + counter res + 1 kHz), spans > 10 MHz |
| Counter resolution | Selectable from 10 Hz to 100 kHz |
| Frequency span | |
| Range | zero span, (10 X N) kHz to 19.25 GHz, (10 X N) kHz to 23.75 GHz (opt 026) |
| Accuracy | ± 2% of span, span < 10 MHz; ± 3% of span, span > 10 MHz |
| Sweep time | |
| Range | 20 ms to 100 s, span = 0 Hz or > 10 kHz; 20 µs to 100 s, span = 0 Hz (opt 101) |
| Accuracy | ± 3%, 20 ms to 100 s, ± 2%, 20 µs to 20 ms |
| Sweep trigger | free run, single, line, video, external |
| Stability | |
| Noise sidebands | -95 dBc/Hz + 20 log N at > 30 kHz offset from CW signal |
| Comb generator | 100 MHz fundamental freq; ± 0.007% freq accuracy |
| AMPLITUDE | |
| Amplitude range | -114 to +30 dBm |
| Maximum safe input level | +30 dBm (1 watt, 7.1 Vrms), 0 Vdc |
| Gain compression | ± 0.5 dB (total power at input mixer = -10 dBm) |
| Displayed average noise level | 114 to < -92 dBm |
| Spurious responses | |
| Second harmonic distortion | < -70 dBc for -40 dBm tone at input mixer, 10 MHz to 2.9 GHz; < -100 dBc for -10 dBm tone power at input mixer or below displayed av noise lev), > 2.75 GHz |
| Third-order intermodulation distortion > 10 MHz | < -70 dBc for two -30 dBm tones at input mixer and > 50 kHz separation |
| Other input-related spurious | < -70 dBc for applied freq & 18 GHz; < -60 dBc for applied freq & 22 GHz |
| Display range | |
| Log scale | 0 to -70 dB from ref lev is calibrated; 1 to 20 dB/div in 1 dB steps; divisions displayed |
| Linear scale | 8 divisions |
| Scale units | dBm, dBmB, dBmicroV, volts, watts |
| Reference level | |
| Range | -114 to +30 dBm |
| Resolution | 0.01 dB for log scale; 0.12% of ref lev for linear |
| Accuracy (ref to -20 dBm ref level) | ± (0.05 dB + input atten acc @ 50 MHz), 0 dBm to -59.9 dBm, ± (1.25 dB + input atten acc @ 50 MHz), -60 to -114 dBm |
| Frequency response (ref to 300 MHz CAL OUT, preselector peaked) | |
| Absolute | ± 2.0 to ± 3.0 dB |
| Relative flatness | ± 1.5 to ± 2.0 dB |
| Calibrator output | |
| Frequency | 300 MHz ± 30 kHz |
| Amplitude | -20 dBm ± 0.4 dB |
| Input attenuator | |
| Range | 0 to 70 dB in 10 dB steps |
| Accuracy at 50 MHz, ref to 10 dB atten | + 0.5 dB, 0 to 60 dB; + 1.2 dB, 70 dB |
| Resolution bandwidth | 1 kHz to 3 MHz, ± 20% |
| Switching uncertianty | ± 0.4 dB, 3 kHz to 3 MHz RBW; ± 0.5 dB, 1 kHz |
| Video bandwidth range | 30 Hz to 1 MHz |
| Log to linear switching | + 0.25 dB at reference level |
| Display scale fidelity | ± 0.2 dB/ 2 dB, 0 to -70 from ref lev, incremental; ± 0.75 dB, 0 to -60 dB from ref lev and ± 1.0 dB, 0 to -70 dB from ref lev, maximum cumulative. |
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved