<< HP 3577B Product PageHP
/ Agilent 3577B
|
| SOURCE | |||
| Frequency | |||
| Range | 5 Hz to 200 MHz | ||
| Resolution | 0.001 Hz | ||
| Stability (Opt 1 only/instrument on ? 48 hrs) | ± 5 X 10-8/day, 0 to 55° C | ||
| Amplitude | |||
| Range | + 15 dBm to -49 dBm (1.26 V rms to 793µ V rms: 2 dB V to -62 dBV) into a 50 Ω load | ||
| Resolution | 0.1 dB | ||
| Accuracy | ± 1 dB at + 15 dBm and 100 kHz. Below +15 dBm, add the greater of ± 0.02 dB/dB or 0.2 dB | ||
| Flatness | 1.5 dB p-p from 5 Hz to 200 MHz | ||
| Impedance | 50 Ω; > 20 dB return loss at all levels | ||
| RF Output Connector | 50 Ω Type N female | ||
| Sweep Types | Linear, discrete, alternate, cw and log frequency; log amplitude | ||
| Sweep Time | 100 ms/span to 6553 sec/span for frequency sweep; 1 ms/step to 16 s/step for amplitude sweep | ||
| Sweep Modes | Continuous, single, manual | ||
| Trigger Modes | Free run, immediate, line, external | ||
| RECEIVER | |||
| Input Characteristics | |||
| Frequency Range | 5 Hz to 200 MHz | ||
| Inputs | Two receiver inputs (A,R); third receiver input (B) is optional | ||
| Input Impedance | Selectable 50 Ω with > 25 dB return loss, or 1 MΩ in parallel with approximately 30 pF | ||
| Input Connectors | 50 Ω Type N female | ||
| Resolution Bandwidth | Selectable 1 kHz, 100 Hz, 10 Hz, or 1 Hz | ||
| Magnitude Characteristics | |||
| Range | Full scale input to sensitivity | ||
| Display Units | dB, dBm, dBV, V, and linear ratio | ||
| Accuracy (at 100 kHz, 25°C, and full scale input) | Absolute
(A, B, R): ± 0.2 dB Ratio (A/R, B/R, A/B): ± 0.15 dB (50 Ω); ± 0.2 dB (1 MΩ) |
||
| Dynamic Accuracy | Error |
Input level relative to full scale input |
|
| Resolution Bandwidth | |||
| 1 kHz, 100 Hz, 10 Hz | 1 Hz | ||
| ± .04 dB ± .02 dB ± .05 dB ± .15 dB ± .75 dB ± .75 dB |
± .04 dB ± .02 dB ± .05 dB ± .25 dB ± .75 dB ± 3.00 dB |
0 dB to
-10 dB -10 dB to -50 dB -50 dB to -60 dB -60 dB to -80 dB -80 dB to -90 dB -90 dB to -100 dB |
|
| Frequency Response (when driven from a 50 Ω source and with 50 Ω receiver input impedance) | |||
| Absolute (A, B, R) | 0.3 dB p-p from 20 Hz to 20 MHz; 0.6 dB p-p from 5 Hz to 200 MHz | ||
| Ratio (A/R, B/R, A/B) | 0.3 dB p-p from 20 Hz to 20 MHz; 0.4 dB from 5 Hz to 200 MHz | ||
| Stability | |||
| Temperature | Typically < ± 0.02 dB/°C | ||
| Time | Typically ± 0.05 dB/hour at 25° C | ||
| Phase Characteristics (A/R, B/R, A/B) | |||
| Range | ±180° | ||
| Accuracy | At 100 kHz, 25°C, and Full Scale Input: ±2.0° | ||
| Dynamic Accuracy |
Error |
Input Level Relative to Full Scale Input |
|
|
± .4 degree |
0
dB to -10 dB -10 dB to -50 dB -50 dB to -60 dB -60 dB to -80 dB -80 dB to -100 dB |
||
| Temperature Stability | Typically < ± 0.05°C | ||
| Time Stability | Typically ± 0.05° hr at 25°C | ||
| Delay Characteristics | |||
| Range | 1 ps to 20,000s | ||
| Resolution | 0.01 ns/div to 1000s/div | ||
| Limit Test | Twenty segments for each trace per limit test. Delay between sweeps approximately 10 to 120 ms. | ||
| GENERAL CHARACTERISTICS | |||
| Traces | |||
| Number of Traces | Two simultaneous traces may be present with a rectangular graticule. One trace with Polar or Smith graticules. | ||
| Markers | Each trace has one main marker and an offset marker. | ||
| Reference Line Position | |||
| Rectangular Graticule | 0% to 100% full scale deflection in 0.05% increments. Logarithmic and linear. | ||
| Polar/Smith Chart Graticule | ± 500° in 0.001° increments. | ||
| Limit Test | Twenty segments for each trace per limit test. Added delay between sweeps approximately 10 to 120 ms. | ||
| Noise Averaging | |||
| Type | Exponentially weighted vector averaging on successive sweep data. | ||
| Averaging Factor | Selectable 1 (off), 4, 8, 16, 32, 64, 128, 256 | ||
| Linear Phase Slope Compensation | Provides linear phase slope offset of -72,000°/span to +72,000°/span. | ||
| Calibration | |||
| Transmission | Both traces can be normalized to measured data with full accuracy and resolution. | ||
| Reflection | Corrects for directivity, frequency response, and source match errors | ||
| Programming | |||
| Remote Programming | Via the Hewlett-Packard Interface Bus (HP-IB). the HP 35677A/B S-parameter test sets are programmable through the HP 3577A interface only. | ||
| Plotter Control | Directly compatible with HP-IB graphics plotters that use Hewlett-Packard Graphics Language (HP-GL) with listen-only capability. | ||
| Save/recall | Front-panel setups can be stored in non-volatile memory locations 1 through 5. Last state is saved when power is removed. | ||
| Operating Conditions | |||
| Temperature | 0°C to +55°C | ||
| Power | 115 V + 10%, -25% (47 Hz to 440 Hz), or 230 V + 10%, -15% (47 Hz to 66 Hz), 450 VA maximum | ||
| Weight | Net, 31 kg (67 lb); shipping, 41 kg (90 lb) | ||
| Size | 222 mm H X 426 mm W X 578 mm D (8.7 in X 16.75 in X 22.75 in) | ||
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved