<< DSP 4000 Main Product
PageFluke DSP4000
|
||||||||||||||||||||||||||||||||||||||||||
| Cable Types | |
| Shielded and Unshielded Twisted Pair (STP and UTP) LAN Cabling: | TIA
Category 3, 4, 5, 5E and 6: 100W ISO/IEC Class C and D: 100W and 120W |
| Foil-Screened Twisted Pair (ScTP): | TIA
Category 3, 4, 5, 5E and 6: 100W ISO/IEC Class C and D: 100W and 120W |
| Shielded Twisted Pair (STP): | 150W IBM Type 1, 6, and 9(adapter required) |
| Coax: | 10BASE5 ThickNet, 10BASE2 ThinNet, RG-58, RG-58 Foam, RG-59, RG-59 Foam, RG-8, RG-8A/U, and RG-62 |
| Fiber: | Multimode and singlemode fiber using fiber test accessories |
| Test Standards | TIA
Category 3 and 5E per Addendum #5 to TIA/EIA-568A TIA Category 5 (new) per TIA TSB-95 TIA Category 6 per TIA Addendum #1 to TIA/EIA-568B (draft) ISO/IEC 11801 Class C and D (new) ISO/IEC 11801-2000 Class C and D (new) STP cabling, (IBM Type 1, 150) ANSI TP-PMD IEEE 802.3 10BASE5, 10BASE2 IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T IEEE 802.5 |
| Speed of Autotest | Full Autotest of Cat 5 UTP cable, including 6 pair combinations for NEXT in both directions, in approximately 10 seconds. |
| Supported Tests | (Range
of test is determined by network or selected standard) NEXT, NEXT @ Remote Wire Map Characteristic Impedance Length DC Loop Resistance Propagation Delay Return Loss (RL), RL @ Remote Delay Skew Attenuation Attenuation-to-Crosstalk Ratio (ACR), ACR @ Remote Power Sum ACR, PSACR @ Remote ELFEXT, ELFEXT @ Remote Power Sum ELFEXT, PSELFEXT @ Remote Power Sum NEXT, PSNEXT @ Remote |
| LAN Traffic | Monitor
provides an audible tone to indicate amount of traffic Monitors 10BASE-T Ethernet traffic using the Monitor RJ45 jack Monitors 100BASE-TX Ethernet traffic using the Monitor RJ45 jack Auto-negotiates between 10BASE-T and 100BASE-TX using the Monitor RJ45 jack Blinks the Link Light on a 10BASE-T, 10/100BASE-TX or a 100BASE-TX hub |
| Cable Tone Generator | Provides a tone generator that can be detected by a handheld tone probe |
Display |
Graphic bit-mapped LCD with back light and adjustable contrast |
Test Connections |
Variable (depending on Link Interface Adapter used) |
Input Protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage |
EMC |
EMC compliant |
Case |
High impact plastic with shock absorbing overmold |
Dimensions |
Main
unit and smart remote including link interface adapter: 11" x 5" x 3" (28 cm x 12.7 cm x 7.6 cm) |
Weight |
Main
unit: 3 lbs., 4 oz (1.5 kg) Smart remote: 3 lbs., 1 oz (1.4 kg) |
Power |
Main
instrument and smart remote: Rechargeable NiMH battery 7.2V, 3400 mAH Typical battery life 10-12 hours, with recharge time of 4 hours May be charged while in the instrument (while operating or off-line) |
Languages Supported |
English, French, German, Spanish, Italian, Portuguese, Japanese, and Simplified Chinese |
Calibration |
Service center calibration period is 1 year. Self-calibration required every 30 days. |
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved