Specification |
PS-3060
PS-3060R |
PS-6030
PS-6030R |
|
Output |
Voltage |
0 to 30V |
0 to 60V |
|
Current |
0 to 6A |
0 to 3A |
Constant
Voltage
Characteristics
(CV Mode) |
Input Regulation |
For AC±10% Fluctuation |
5mV |
8mV |
|
Load Regulation |
For 0 to 100% Fluctuation |
5mV |
8mV |
|
Ripple and Noise |
10Hz to 1MHz |
1mVrms |
|
Ripple Peak |
10Hz to 20MHz |
4mVp-p |
|
Transient Response |
Standard Value
(Current 5% to 100%) |
50u Typical |
|
Temperature Coefficient |
Standard Value |
100ppm/°C Typical |
Constant Current
Characteristics
(CC Mode) |
Input Regulation
|
For AC±10% Fluctuation |
6mA |
3mA |
|
Load Regulation |
For 0 to 100% Fluctuation |
15mA |
15mA |
|
Ripple and Noise |
10Hz to 1MHz |
3mA rms |
2mA rms |
|
Temperature Coefficient |
Standard Value |
250ppm/°C Typical |
|
Digital Meter Indication |
Voltmeter Indication |
Red 3-digit LED |
Max 99.9V, Fixed Range |
|
Accuracy |
Output ON |
± (0.2% rdg + 2digits) |
|
Ammeter Indication |
Red 3-digit LED |
Max 99.9V, Fixed Range |
|
Accuracy |
Output ON |
± (1.0% rdg + 3digits) |
|
Insulation Resistance |
Between Chassis and Input Power
Supply |
DC500V 30MΩ |
|
Between Chassis and Output
Terminal |
DC500V 20MΩ |
|
Power Supply |
Line Voltage Range |
Voltage Fluctuation
within 10% |
AC100V/120V/220V/230V
(selectable), 50/60Hz |
|
Power Consumption |
Approx. |
450VA/370W |
380VA/300W |
| Constant Voltage Operation
Indication |
CV (Green LED) Light |
| Constant Current Operation
Indication |
CC (Red LED) Light
|
| Output Polarity |
+(Red), -(White), GND (black)
±grounding is possible |
| Operating Temp and Humidity
Range |
0 ~ 40°C, 10 ~ 80% RH |
| Storage Temp and Humidity Range |
-20 ~ 60°C, 10 ~ 85% RH |
| Ground Proof Voltage |
±200V |
| Dimensions (WxHxDmm) |
210*163*347 |
210*163*347 |
| Weight (Approx) |
10.0kg |
10.0kg |
Remote
(PS-3060R/
PS-6030R/
only) |
Controlled by
external
voltage 0 to 10V |
Output Voltage |
0 to 30V±5% |
0 to 60V±5% |
|
Output Current |
0 to 6A±5% |
0 to 3A±5% |
Controlled by
external
resistance 0 to 10 kΩ
|
Output Voltage |
0 to 30V±5% |
0 to 60V±5% |
|
Output Current |
0 to 6A±5% |
0 to 3A±5% |
|
Remote sensing |
Possible by using
the (+S) and
(-S) terminals on the panel Compensation
possible up to 1V one way |
|
Series Operation |
Master/
slave mode |
One control series
operation is possible
(within the ground proof voltage) |
|
Parallel Operation |
Master/
slave mode |
One control series
operation is possible
(only for same model) |