<< UniSource Oscilloscopes
UniSource S 2401
1 MHz Handheld Digital Storage Scope Meter
|
- Dual Channel and Auto Calibration.
- DC to 1 MHz (
S 2401 ) / 5 MHz
( S 2405 ) Oscilloscope
band width
- Sampling Time : Dual CH mode: 25 Ms/S, Single
CH mode: 50 Ms/S
- Auto Calibration
- Auto Triggering
- Automatic setting for horizontal and vertical
division
- Roll and Single shot mode
- Excellent internal noise reduction
- Real time Update.
- Auto ranging.
- 16 shot waveform and setup memories
- Built-in auto ranging True-RMS digital
multi-meter
- Data hold and run mode.
- Extra bright backlight display
Frequency Measurement : 100Hz~1MHz
- Maximum Input voltage : DC or AC 600Vrms
- RS-232 interfaces for transferring
measurement data and waveform.
- 132 by 128 pixels super-twist LCD display
- Low battery indication.
|
 
UniSource S2401 Shown
|
|
|
|
Oscilloscope Function |
|
Model |
S2401 |
| Horizontal |
| Sample Rate |
50MS/s (Single CH) / 25MS/s (Dual
CH) |
| Record Length |
512 in single shot mode and 256 in
all other modes. |
| Sample / Div |
25 |
| Update Rate |
Real Time |
| Modes |
Single shot, Roll, Normal |
| Accuracy |
0.01% |
| Sweep Rate |
1µS to 5S in 1, 2, 5 sequence |
|
Vertical |
| Bandwidth |
DC-1MHz(S2401), DC-5MHz(S2405) |
| Resolution |
8 Bit |
| Channels |
Dual |
| Coupling |
AC, DC |
| Input impedance |
1 M? |
| Accuracy |
3% |
| Max. Input Volts |
DC or AC 600Vrms |
| Volt / Division |
0.5V to 500V in 1, 2, 5 sequence |
|
Triggering |
| Type |
Internal, External |
| Coupling |
AC, DC |
| Slope |
or ¯ edge |
| Internal Sensitivity |
2 / 20 Division |
|
Other |
| Wave Form Memory |
16 Shots |
|
|
|
|
Digital Multimeter Function |
|
DC V |
Range |
Resolution |
Accuracy |
Impedance |
| 5V |
0.001V |
±(0.3%+3) |
1 MΩ |
| 50V |
0.01V |
| 500V |
0.1V |
±(0.5%+5) |
| 1000V |
1V |
|
ACV |
Range |
Resolution |
Accuracy |
Impedance |
|
50~450Hz |
0.45k~5kHz |
5k~20kHz |
| 3V |
0.001V |
±(0.75%+5) |
±(2%+5) |
±(2.5%+5) |
1 MΩ |
| 30V |
0.01V |
| 300V |
0.1V |
| 750V |
1V |
N/A |
|
OHM |
Range |
Resolution |
Accuracy |
Over Load
Protection |
| 5 kΩ |
0.001 kΩ |
±(0.5%+5) |
600V DC
or AC rms |
| 50 kΩ |
0.01 kΩ |
| 500 kΩ |
0.1 kΩ |
| 5 MΩ |
0.001 MΩ |
±(0.75%+10) |
|
Continuity Buzzer |
Test
Voltage |
Threshold |
Over
Load Protection |
| 1.7V |
100
digits |
600V DC
or AC rms |
|
Frequency
(Full Auto Range)
(10MHz is SS2405 only) |
Range |
Resolution |
Accuracy |
Over
Load Protection |
| 100 HZ |
0.01 Hz |
±(0.05%+5) |
600V DC or AC rms |
| 1 kHz |
0.0001 kHz |
| 10 kHz |
0.001 kHz |
| 100 kHz |
0.01 kHz |
| 1MHz |
0.0001 MHz |
10MHz
(S2405 only) |
0.001 MHz |
|
RPM |
Range |
Resolution |
Accuracy |
| 240 – 60,000 |
1 RPM |
±(0.05%+5) |
|
Pulse Width |
Range |
2µS – 500mS (Pulse
Width > 2µS) |
|
% Duty |
Range |
25% - 75% |
|
General |
Power Requirement |
Ni-MH Battery 4.8V
(1.2V x 4 cell) |
| Battery Life Time |
4 Hours with Backlight