Specifications |
|
DC Amps |
|
Ranges |
400
Amps and 1000Amps |
|
Best Resolution |
0.1 mA |
|
Accuracy |
±(3.0%
+ 5 dgt.) |
|
Max |
1000
Amps DC |
|
DC Amps |
|
Ranges |
400
Amps and 1000Amps |
|
Best Resolution |
0.1 mA |
|
Accuracy |
±(2.5%
+ 5 dgt.) < 600 Amps
±(3.0% + 5 dgt.) ≥ 600 Amps |
|
Max |
1000
Amps AC |
|
Volts DC |
|
Ranges |
4V,
40V, 400V, 1000V |
|
Best Resolution |
1 mV |
|
Accuracy |
±(0.8%
+ 3 dgt.) |
|
Max |
10MW |
|
Resistance |
|
Ranges |
400W, 4KW, 40KW, 400KW, 4MW, 40MW |
|
Best Resolution |
100 mW |
|
Accuracy |
±(1.0%
+ 5 dgt.) |
|
Frequency (Input
Terminals) |
|
Ranges |
40Hz
to 100KHz |
|
Best Resolution |
0.1 Hz |
|
Accuracy |
±(0.1%
rdg + 2 dgt.) |
|
Frequency (Input
Terminals) |
|
Buzzer will sounds |
<40W
Resistance |
|
General Specifications |
|
Power |
(3)
1.5V AAA Batteries |
|
Size |
9"(L)
x 3.4"(W) x 1.3"(D) |
|
Weight |
1 lb |
|
Accessories |
Test