Model |
Sensitivity |
Voltage
(min-max) |
Apparatus |
Testing
Requirements |
|
MIT200 |
1000 MΩ |
250 - 1 kV |
Domestic and industrial systems,
site maintenance and service departments, transformers,
motors, generators, switchgear, panel building, domestic
appliances, power tools etc., fixed electrical wiring
systems |
|
|
MIT210 |
|
MIT220 |
|
MIT230 |
|
MIT300 |
999 MΩ |
250 - 500 V |
Domestic, Commercial and
industrial wiring, Panels, motors, generators, switchgear,
power tools, street lighting |
Standard voltage testing with
moderate sensitivity required; rugged and physically demanding
test environments; simplified operation |
|
MIT310 |
250 - 1 kV |
|
MIT310A |
|
MIT320 |
|
MIT330 |
|
MIT400 |
20 GΩ |
250V, 500V, 1000V |
Domestic, industrial service, and
maintenance Manufacturing, production testing, Electrical
installation, Panel building, Railway and other
transportation |
|
|
MIT410 |
100 GΩ |
50V, 100V, 250V,
500V, 1000V |
|
MIT420 |
200 GΩ |
|
MIT430 |
|
MIT40X |
2 - 20 GΩ
Depending on voltage |
10V to 100V
variable
(1V
increments) |
|
MIT480 |
100 GΩ |
50V, 100V |
Domestic, industrial service, and
maintenance Manufacturing, production testing, Electrical
installation, Panel building, Railway and other
transportation, Telecommunications industry |
|
|
MIT481 |
200 GΩ |
50V, 100V, 250V,
500V, 1000V |
|
MIT485 |
|
BM15 |
20 GΩ |
500 - 5 kV |
Lower quality transformers,
motors, capacitors, power cables |
Higher Voltage required for
testing but sensitivity less important |
|
MJ15 |
|
210400 |
100 GΩ |
5 kV |
For highly sensitive
insulation-resistance measurements of all types of
electrical equipment and power cable. |
|
|
210415 |
300 GΩ |
15 kV |
|
|
210170 |
20 GΩ |
100 - 1 kV |
15-kV and below power cable,
small motors, appliances, power tools |
Standard voltage testing with
higher sensitivity requirements, broad voltage range |
|
210600 |
2 GΩ |
100 - 1 kV |
15-kV and below power cable,
small motors, appliances, power tools |
Standard voltage testing with
lower sensitivity requirements, broad voltage range |
|
MIT510 |
15 TΩ |
500 - 5 kV |
Large transformers, large motors,
switchgear, large capacitors, high-voltage cabling |
High level sensitivity
requirements, enhanced troubleshooting for continuity |
|
MIT520 |
50 - 5 kV |
Large transformers, large motors,
switchgear, large capacitors |
Highest level sensitivity for
long term preventative maintenance testing, catastrophic
change testing |
|
MIT1020 |
35 TΩ |
50 - 10 kV |
Specifically, rotating machinery
rated > 12 kV; generally, any heavy equipment with
high-voltage ratings |
Maintenance of high-voltage