| Model |
|
PDS20-18 |
PDS20-36 |
PDS36-10 |
PDS36-20 |
PDS60-6 |
PDS60-12 |
PDS120-6 |
|
Output |
Power
Output Watts |
360W |
720W |
360W |
720W |
360W |
720W |
720W |
| Output
Voltage Volts |
0~20V |
0~20V |
0~36V |
0~36V |
0~60V |
0~60V |
0~120V |
| Output
Current Amps. |
0~18A |
0~36A |
0~10A |
0~20A |
0~6A |
0~12A |
0~6A |
|
Voltage
Regulation Characteristics |
Line Regulation |
0.005%+1mV
(with respect to ±10% variation in AC) |
| Load Regulation |
0.005%+2mV
(with respect to change from 0 to 100) |
| Ripple/Noise
(By 20MHz Scope) p-p |
30mVp-p |
| Ripple/Noise
(5-1MHz) ms |
1mVrms |
1.5mVrms |
1mVrms |
2mVrms |
|
Display |
Voltage Display,
Accuracy |
4 digits LED, 0.1% rdg ± 2 digits (23±5°C) |
3 digits LED,
0.1% rdg ± 2 digits (23±5°C) |
4 digits LED, 0.1% rdg ± 2
digits (23±5°C)
|
| Voltage Resolution |
10mV |
100mV |
| Current Display,
Accuracy |
4 digits LED,
0.5% rdg ± 2 digits (23±5°C) |
3 digits
LED, 0.5% rdg ± 2 digits (23±5°C) |
4 digits
LED, 0.5% rdg ± 2 digits (23±5°C) |
3 digits
LED, 0.5% rdg ± 2 digits (23±5°C) |
| Current Resolution |
10mA
|
|
Protection |
Over Voltage
Protection |
Power
switch off at setting value |
| Over Current
Protection |
Power
switch off at setting value |
| Over Heat
Protection |
Power
switch off if over-heated |
|
Power Requirement |
AC Input Voltage |
AC90 to
250V 50/60Hz |
| Power Factor
typ. |
95% typ. |
| Power
Consumption |
560W |
1100W |
520W |
1050W |
520W |
1050W |
1050W |
| Power Efficiency
typ. |
65% |
65% |
70% |
70% |
72% |
72% |
72% |
|
Dimensions/Weight
|
Dimensions W X H
X D |
210
X 124 X 405 (210 X 141 X 465.5) |
210
X 124 X 405 X (210 X 141 X 425.5) |
| Weight approx. |
6.3kg |
7.2kg |
6.3kg |
7.2kg |
6.3kg |
7.2kg |
7.2kg |
|
Options |
GP-IB Interface
Card |
V&I
set/read, Output On/Off, AC shout down |
| RS-232C
Interface Card |
V&I
set/read, Output On/Off, AC shout down |
| Analog Interface
Card |
V/I
controlled by external voltage or resistance |
| Output Capacity
Extension |
Parallel
connection control: Master slave system, up to 3 units
Series connection control: Master-slave system, up to 2 units |
| Warranty |
3 years |