Kenwood PEL Series
|
| Model | PEL151-201 | PEL301-201 | |
| Constant Current Mode | Range/Resolution |
L Range: 0.3 A: 0~0.3 A/10 µA 1.5 W max |
L Range: 0.6 A: 0~0.6 A/20 µA 3 W max |
| Accuracy | ±0.2% of SET ±0.3% of FS (0~40°C) | ||
| Ripple Noise (1 MHz) |
L Range: 1 mA rms |
||
| Stability | ±0.1% of FS (typ) | ||
| Input Power | 0~150 W | 0~300 W | |
| Input Voltage Range | CR Mode: 0~200 V, CC/CP/CV Mode: 1.5~200 V | ||
| Input Current Range (Front/Rear Terminal) | 0~30 A/0~30 A | 0~60 A/0~30 A | |
| Constant Resistance Mode | Range |
H
Range: OPEN, 1.5 k~0.5/ 0.498~50 mW |
H
Range: OPEN, 750~0.25/0.249~25 mW |
| Resolution | H
Range: 0.66ms L Range: 6.6µs |
H
Range: 1.33 ms L Range: 13.3 µs |
|
| Accuracy (23°C±5°C) |
H
Range: ±0.5% SET ±0.15A+Vin/Rin |
H
Range: ±0.5% SET ±0.3 A+Vin/Rin |
|
| Ripple Noise (1 MHz) |
L Range: 1 mA rms |
||
| Temperature Factor | 1000PPM/°C (Vin=5 V) | ||
| Constant Voltage Mode | 20 V Range/200 V Range |
1.5~20 V/15~200 V (CC+CV Mode, CR+CV Mode) |
|
| Accuracy/Resolution/ Minimum Operating Current | ±0.1%
of SET ±0.1% of FS (0~40°C) 20 V Range: 1 mV 200 V Range: 10 V/1% of Constant Current |
||
| Constant Power Mode | Operating Range/ Resolution | 1.5 W
Range: 0.03~1.5 W/ 50 µW 150 W Range: 3~150 W/ 5 mW |
3 W
Range: 0.06~3 W/ 100 µW 300 W Range: 6~300 W/ 10 mW |
| Accuracy (23°C±5°C) | ±0.4% SET ±1.6%FS ±Vin X Vin/Rin (Vin X Vin/Rin for Current L Range) (TEMP Factor: 1000PPM/°C (Vin=5V)) | ||
| Ripple Noise (1 MHz) |
L Range 1 mA rms, H Range 10 mA rms |
||
| Short Mode | Setting Current Value | 0.3/30 A (V1 model CC0V: 18 A) |
0.6/60 A (V1 model CC0V: 18 A) |
|
SW
Mode (Preset AÛB) |
Frequency/Accuracy | 1Hz~10kHz/±1.5% SET | |
| DUTY/Setting Accuracy/Resolution | 5%~95%/±1.5% SET/1% STEP | ||
|
Through
Rate Tr/Tf (1%Û100%) |
Operating Mode | CC, CR | |
| Setting Range |
CC:10/20/50/100/200/500/1000/2000µs, CR: OFF /200/500/1000/2000µs |
||
| Setting Accuracy |
H:10, 20µs:-5µs: ±10µs,
L: 10, 20µs: ±10µs |
||
| Soft Start | Operating Mode | CC | |
| Setting Range/ Accuracy |
0.1/1/2/5/10/20/50/100ms/±30% set+100µs |
||
| Remote Sensing | 2.5V par One Way | ||
| External Control | Voltage |
0~10V (Offset gain Adjustable at Rear Panel.) It takes approx. 1 Second for Settings at CR Mode |
|
| Resistance |
0~10kW (It takes approx. 1 Second for Settings) |
||
| Others | LOAD ON/OFF, EXT SW | ||
| Series/Parallel (Master/Slave Operation) | Connecting Capability | Maximum 4 of Slave Units plus 1 Master Unit | |
| Added Current Display |
Total Value of Slave Unit(s) and Master Unit are Displayed at Master Unit Display. Over Write: 2 times/sec |
||
| Resolution
(L Range/ H Range) |
0.1
X N/10 X N (mA) N: Parallel Unit Numbers. |
0.2
X N/20 X N (mA) N: Parallel Unit Numbers. |
|
| Current Monitor Out | Linearity | ±1% FS (Offset and gain are Adjustable.) | |
| DC Current Measurement | Range/(Resolution) | 0.3/30A/(0.1/10mA) | 0.6/60A/(0.1/10mA) |
| Accuracy/Repeat | ±0.2% rdg ±0.3% FS (0~40°C)/2 Times/Sec | ||
| DC Voltage Measurement | Range/Resolution | 20.000/210.00 Vmax (Auto Range)/ 1 mV (0~20 V)/ 10 mV (20~210 V), Hysteresis at 18/20 V | |
| Accuracy/Repeat/ Temperature Factor | 20V Range: ±0.03% rdg ±0.06% FS, 200V Range:±0.03% rdg ± 0.03% FS (18~28°C)/ 2 Times/Sec/ ±0.003% rdg ±0.003% FS/°C) | ||
| Power Measurement | Range/Resolution |
1.5/150 W (1/100 mW)/2 Times/Sec (Voltage X Current) |
3/300 W (1/100 mW)/2 Times/Sec (Voltage X Current) |
| UVP (Under Voltage) | Range/Resolution/ Accuracy |
OFF:-0.5~20 V/20 mV/±0.1% SET ±40 mV (0~40°C) |
|
| OPP (Over Power) | Range/Resolution |
L: 0.15~1.65 W/10 mW |
L: 0.3~3.3 W/20 mW |
| Setting Accuracy | ±0.2% SET ±2 W (0~40°C) | ±0.2% SET ±4W (0~40°C) | |
| OCP (Over Current) | Setting Range/ Resolution | L: 0.03~0.33 A/1.5 mA H: 3~33 A/150 mA |
L: 0.06~0.66 A/3 mA H: 6~66 A/300 mA |
| Setting Accuracy | ±0.2% SET ±300 mA (0~40°C) | ±0.2% SET ±600 mA (0~40°C) | |
| Protection | Over Voltage | Cut Load Off about 230 V | |
| Over Current, Over Power | Automatic Resume After 3 Sec of Load Off | ||
| Reversed Connection | Terminate by Parasitic FET | ||
| Over Heating | Cut Load Off at 110°C at Inside Heat Sink | ||
| Sequence Memory | Step/Time/Resolution | 100/50 µs~99h59m59.99995s, PAUSE, PASS/50µs/Cycle: 1~255 | |
| Items | Discharge Mode Pre-set A, B and C Value, Pre-set A, B, and C Switch selection, Discharge Mode, SHORT Mode ON/OFF, LOAD ON/OFF, UVP Setting value, OCP Setting Value, OPP Setting Value, Soft Start Setting Value, Tr/Tf Setting Value, SW Frequency, SW DUTY, CV RANGE, Current RANGE, External Control Mode (PASS at Auto Sequence Mode) | ||
| Environmental Request | Temperature/ Humidity |
0~40°C 20~85%RH/-20~60°C 20~85%RH |
|
| Power Source/ Frequency | AC90~132V/AC180~250V 48~63Hz | ||
| Power Factor | Less than 75 VA | Less than 77 VA | |
| Isolation | Primary
to Body: 1500 VAC 1 Minute Primary to Secondary: 2300 VAC 1 Minute |
||
| Isolation Resistance | Primary
to Body, Primary to Secondary: 500 VDC More than 10 MW Secondary to Body: 250 VDC More than 5 MW |
||
| Cooling Method | Cooling Fan | ||
| Dimension/Weight | W X H X D: 213 X 133 X 450 (mm)/ Approx. 6kg | W X H X D: 213 X 133 X 450 (mm)/ Approx.7kg | |
| Constant Current Mode (H Range Only) | Range/Constant Resolution | 0~18 A/1 mA 100 W max | 0~18 A/2 mA 200 W max |
| Ripple Noise (1 MHz) | 20 mA rms | ||
| CC ZERO
VOLTS DISCHARGE MODE (V1 VERSION FOR CC0V) |
PEL151-201V1 | PEL301-201V1 | |
| Terminal |
Front terminal for CC0V Discharge Mode |
||
| Input Current Range | 0~18 A | ||
| Through Tr/Tf | Constant Range | CC: 500/1000/2000 µs | |
| Environmental Request | Power Factor | Less than 250 VA | Less than 250 VA |
| Warranty | 3 years | ||
| Model | PEL601-201 | PEL102-201 | |
| Constant Current Mode | Range/Resolution | H Range:
120 A: 0~120 A/ 4mA 600 W max L Range: 1.2 A: 0~1.2 A/ 40 µA 6 W max |
H Range:
200 A: 0~200 A/ 5 mA 1000 W max L Range: 2 A: 0~2 A/50 µA 10 W max |
| Accuracy |
±0.2% of SET ±0.3% of FS (0~40°C) |
||
| Ripple Noise (1 MHz) | H Range:
20 mA rms/ L Range: 2 mA rms |
H Range:
30 mA rms/ L Range: 3 mA rms |
|
| Stability | ±0.25% of FS (typ) | ±0.35% of FS (typ) | |
| Input Power | 0~600 W | 0~1000 W | |
| Input Voltage Range |
CR Mode: 0~200 V, CC/CP/CV Mode: 1.5~200 V |
||
| Input Current Range (Front/Rear Terminal) | 0~30 A/0~120 A | 0~30 A/0~200 A | |
| Constant Resistance Mode | Range |
H Range: OPEN, 375 W~12.5
mW |
H Range: OPEN, 250
W~8.3
mW L Range: OPEN, 25 kW~833 mW |
| Resolution | H Range: 2.66 ms/ L Range: 26.6 µs |
H Range: 4ms/ L Range:40µs |
|
| Accuracy (23°C±5°C) | H Range: ±0.5% of
SET ±0.6 A + Vin/Rin L Range: ±0.5% of SET ±6 mA + Vin/Rin |
H Range: ±0.5% of
SET ±0.9 A + Vin/Rin L Range: ±0.5% of SET ±9 mA + Vin/Rin |
|
| Ripple Noise (1 MHz) | H Range:
20 mA rms/ L Range: 2 mA rms |
H Range:
30 mA rms/ L Range: 3 mA rms |
|
| Temperature Factor |
1000PPM/°C (Vin=5 V) |
||
| Constant Voltage Mode | 20 V Range/200 V Range |
1.5~20 V/15~200 V (CC+CV Mode, CR+CV Mode) |
|
| Accuracy/Resolution/ Minimum Operating Current | ±0.1%
of SET ±0.1% of FS (0~40°C) 20 V Range: 1 mV 200 V Range: 10 V/1% of Constant Current |
||
| Constant Power Mode | Operating Range/ Resolution | H Range:
6~600 W/ 20 mW L Range:0.12~6 W/200 µW |
H
Range:10~1000 W/25 mW L Range: 0.2~10 W/250 µW |
| Accuracy (23°C±5°C) | ±0.4% SET ±1.6%FS ±Vin X Vin/Rin (Vin X Vin/Rin for Current L Range) (TEMP Factor: 1000PPM/°C (Vin=5V)) | ||
| Ripple Noise (1 MHz) | H Range: 20 mA
rms/ L Range: 2 mA rms |
H Range:
30 mA rms/ L Range: 3 mA rms |
|
| Short Mode | Setting Current Value | 1.2/120 A (V1 model CC0V: 18 A) |
2/200 A (V1 model CC0V:18 A) |
| SW
Mode (Preset AÛB) |
Frequency/Accuracy |
1 Hz~10 kHz/±1.5% SET |
|
| DUTY/Setting Accuracy/Resolution |
5%~95%/±1.5% SET/1% STEP |
||
| Through
Rate Tr/Tf (1%Û100%) |
Operating Mode | CC, CR | |
| Setting Range | CC:
10/20/50/100/200/500/1000/2000µs, CR: OFF/200/500/1000/2000µs |
||
| Setting Accuracy |
H: 10, 20 µs: -5 µs:
±10 µs, |
||
| Soft Start | Operating Mode | CC | |
| Setting Range/ Accuracy | 0.1/1/2/5/10/20/50/100 ms/±30% of set + 100 µs | ||
| Remote Sensing | 2.5 V par One Way | ||
| External Control | Voltage | 0~10 V (Offset gain Adjustable at Rear Panel.) It takes approx. 1 second for settings at CR Mode. | |
| Resistance | 0~10 kW (It takes approx. 1 second for settings) | ||
| Others | LOAD ON/OFF, EXT SW | ||
| Series/Parallel (Master/Slave Operation) | Connecting Capability | Maximum 4 of Slave Units plus 1 Master Unit | |
| Added Current Display |
Total Value of Slave Unit(s) and Master Unit are Displayed at Master Unit Display. Over Write: 2 times/sec. |
||
| Resolution (L Range/H Range) |
0.4 X N/40 X N (mA) N: Parallel Unit Numbers. |
0.6 X N/60 X N (mA) N: Parallel Unit Numbers. |
|
| Current Monitor Out | Linearity |
±1% FS |
|
| DC Current Measurement | Range/ (Resolution) | 1.2/120A/(0.1/10 mA) | 2/200A/(0.1/10 mA) |
| Accuracy/Repeat | ±0.2% of rdg ±0.3% of FS (0~40°C)/ 2 times/sec | ||
| DC Voltage Measurement | Range/Resolution | 0~20 V/1 mV, 20~210 V/10 mV (Auto Range, Hysteresis at 18/20 V) | |
| Accuracy/Repeat/ Temperature Factor | 20 V Range: ±0.03% of rdg ±0.06% of FS, 200 V Range: ±0.03% of rdg ±0.03% of FS (18~28°C)/2 times/sec | ||
| Power Measurement | Range/Resolution | 6,600
W/1,100 mW (Voltage X Current) |
10,100
W/1,100 mW (Voltage X Current) |
| UVP (Under Voltage) | Range/Resolution |
OFF, -0.5 ~20 V/20 mV |
|
| OPP (Over Power) | Range/Resolution | H Range: 60~660
W/4 W L Range: 0.6~6.6 W/40 mW |
H Range: 100~1100
W/8 W L Range: 1~11 W/80 mW |
| OCP (Over Current) | Setting Range/Resolution | H Range: 12~132
A/600 mA L Range: 0.12~1.32 A/6 mA |
H Range: 20~220
A/1 A L Range: 0.2~2.2 A/10 mA |
| Protection | Over Voltage | Cut Load Off about 230 V | |
| Over Current, Over Power | Automatic Resume After 3 sec of Load Off | ||
| Reversed Connection | Terminate by Parasitic FET | ||
| Over Heating | Cut Load Off at 110°C at Inside Heat Sink | ||
| Sequence Memory | Step/Time/Resolution | 100/50
µs~99h
59m 59.99995s, PAUSE, PASS/50µs Cycle: 1~255 |
|
| Items | Discharge Mode Pre-Set A, B, and C Value, Pre-set A, B, and C Switch Selection, Discharge Mode, SHORT Mode ON/OFF, LOAD ON/OFF, UVP Setting Value, OCP Setting Value, OPP Setting Value, Soft Start Setting Value, Tr/Tf Setting Value, SW Frequency, SW DUTY, CV RANGE, Current RANGE, External Control Mode (PASS at Auto Sequence Mode) | ||
| Environmental Request | Temperature/Humidity | 0~40°C/20~85% RH | |
| Power Source | AC90~132 V/AC180~250 V, 48~63 Hz | ||
| Power Consumption | Less than 84 VA | Less than 100 VA | |
| Isolation | Primary to Body: 1500 VAC 1 Minute, Primary to Secondary: 2300 VAC 1 Minute | ||
| Isolation Resistance | Primary to Body, Primary to Secondary: 500 VDC More Than 10 MW, Secondary to Body: 250 VDC More Than 5 MW | ||
| Cooling Method | Cooling Fan | ||
| Dimensions (Maximum) |
W X H X D: 421.5 (421.5) X 124 (132.5) X 405 (538) mm |
||
| Weight | Approx. 11 kg | Approx. 13 kg | |
| CC Zero Volts Discharge Mode (V1 Version for CC0V) | PEL601-201V1 | PEL102-201V1 | |
| Constant Current Mode (H Range Only) | Range/Constant Resolution | 0~18 A/2 mA 400 W max | 0~18 A/2 mA 600 W max |
| Ripple Noise (1 MHz) | 30 mA rms | ||
| Terminal | Front Terminal for CC0V Discharge Mode | ||
| Input Current Range | 0~18 A | ||
| Through Tr/Tf | Constant Range |
CC: 500/1000/2000µs |
|
| Environmental Request | Power Consumption | Less Than 250 VA | Less Than 265 VA |
| Warranty | 3 years | ||
$20.00 Minimum on Total Order
Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________
99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:
Copyright © Fotronic Corporation All Rights Reserved