| Specifications |
| DC Voltage range |
560.0 mV to 1000 V, 5 ranges
Best accuracy: ±0.35 % rdg. ±2 dgt. |
| AC Voltage range |
560.0 mV to 750 V, 5 ranges
Best accuracy: ±1.5 % rdg. ±4 dgt. , Effective value rectifier |
| Frequency characteristics at AC Voltage |
560.0 mV to 560.0 V: 50 to 2 kHz
750 V: 50 to 500 Hz |
| Resistance range |
560.0 ohm to 56.00 M-ohm, 6 ranges
Best accuracy: ±0.5 % rdg. ±4 dgt. |
| DC Current range |
56.00 µA to 10.00 A, 6 ranges
Accuracy: ±1.5 % rdg. ±4 dgt. |
| AC Current range |
56.00 µA to 10.00 A, 6 ranges
Best accuracy: ±2.5 % rdg. ±4 dgt. , Effective value rectifier |
| Frequency characteristics at AC Current |
50 to 2 kHz |
| Frequency range |
4.00 Hz to 400.0 kHz, 5 ranges
Input level: 400 mV to 750 V rms
Accuracy: ±0.02 % rdg. ±1 dgt. |
| Continuity |
Possible (100 ohm ±80 ohm) or less |
| Diode check |
Possible (1.7 V open terminal voltage) |
| Other functions |
Hold-auto function, Duty factor measurement,
Relative function, 10 A/600 V Bussmann fuse |
| Auto power save |
Possible (Cancel possible) |
| Range switching |
Auto or Manual |
| Display |
LCD, maximum 5610 dgt. (all mode), maximum 14999
dgt. (Frequency)
Bar graph display: Maximum 56 segments |
| Sampling rate |
2.5 times/sec (all mode), 2 times/sec (Frequency),
20 times/sec (Bar graph) |
| Power supply |
R03(AAA) × 2 dry batteries (Continuous use 500
hours) |
| Dimensions, mass |
76 mm(2.99 in)W × 167 mm(6.57 in)H × 33 mm(1.30
in)D, 300 g (10.6 oz) |