| Specifications |
| Model 3118-11 |
250 V DC (testing voltage), 50 M-ohm (rated
resistance), First effective measurement range and tolerances ±5 %
of scale indication at 0.05 M-ohm to 20 M-ohm,
500 V DC (testing voltage), 100 M-ohm (rated resistance), First
effective measurement range and tolerances ±5 % of scale indication
at 0.1 M-ohm to 50 M-ohm, AC voltage scale 0 to 600 V (50/60 Hz) ±7
% f.s. |
| Model 3118-12 |
500 V DC (testing voltage), 200 M-ohm (rated
resistance), First effective measurement range and tolerances ±5 %
of scale indication at 0.1 M-ohm to 50 M-ohm,
1000 V DC (testing voltage), 2000 M-ohm (rated resistance), First
effective measurement range and tolerances ±5 % of scale indication
at 2 M-ohm to 500 M-ohm,AC voltage scale 0 to 600 V (50/60 Hz) ±7 %
f.s.
|
| Low resistance range |
0 to 100 ohm, ±3 % of scale length |
| Other functions |
Battery check function, discharge function |
| Power supply |
R6P(AA) manganese batteries × 6 or AC adapter
(8.5 V, 600 mA) |
| Dimensions, mass |
106 mm(4.17 in)W × 145 mm(5.71 in)H × 52
mm(2.05 in)D, 500 g (17.6 oz) |
|