New features added to version 4.3
- Support for Model 917x series
Metrology Wells as heat sources
- Support for Model 9112A and 9112B Furnaces
- Bug fix for logging into MET/TRACK database on non-English
systems
- MET/TEMP II now ships with a USB to RS-232 adapter included!
Few things matter in your work more than productivity. And few
things can help make you more productive than well-written
automation software. We've got the world's best temperature
calibration automation software-exactly what you need to be
productive. It's Windows based and it's easy to use.
You may be familiar with the Hart automation software duo
Calibrate-it & Generate-it. Now both come in a single package
called MET/TEMP II. Written by the same Hart temperature experts
that brought you the original Calibrate-it & Generate-it software,
this new package interfaces with Fluke's MET/TRACK. Calibrating
sensors manually is expensive because of labor costs. It takes
roughly four hours to calibrate a sensor at three points, then
another hour on top of that for paperwork to document the
temperature data and to create the certificate. This is much too
time-consuming. Now there's a better way. With MET/TEMP II, you
simply place your test sensors in a heat source, connect them to a
readout, and enter your setup data into your PC. Sometime later, hit
your print button, take the reports out of your printer, sign them,
and ship the sensors back to your customer. Your customers will love
the fast turnaround. It's your choice. Spend four hours the old
way and handle everything manually, or fifteen minutes with Hart's
software and have plenty of time to read your e-mail. This
software package tests thermocouples (all types), RTDs, SPRTs,
thermistors, and even liquid-in-glass thermometers (LIGs). Virtually
any sensor with a resistance or voltage output can be tested, up to
100 sensors at a time. They don't even have to be the same type. You
can select as few as 1 or as many as 40 temperatures at which to
test your sensors. Nobody makes more ultra-stable heat sources and
thermometer readouts for temperature calibration work than Hart
Scientific. MET/TEMP II can use virtually every one of them. You
don't need to worry about special software drivers for each
different piece of equipment. Just plug and play. Use MET/TEMP II
with these instruments: Reference Thermometers/Scanners
- 1590 Super-Thermometer II (2590 Mighty Mux II optional)
- 1575/1575A Super-Thermometer (2575 Mighty Mux optional)
- 1560 Black Stack (with any combination of modules)
- 1502, 1502A, 1503, 1504 Tweener Thermometers
- 1521, 1522 Handheld Thermometers
- 1529 Chub-E4 Thermometer
- Fluke Hydra Series II dataloggers
Heat Sources
- Hart's new 917x series Metrology Wells
- All Hart baths with RS-232
- All Hart dry-blocks with RS-232
- Hart furnaces 9112, 9113, 9114 and 9150
- Hart furnaces 9210 and 9260 (when used for comparison
only)
- Hart IR Calibrators 9132 and 9133
- Hart controllers models 2100, 2200 and 7900
- Fluke dry-block models 514, 515, 517, 518
- Any other heat source (temperatures must be set
manually)
|

|
|
Did we mention that MET/TEMP II also works with the Fluke
Hydra Series II data loggers?
You can even calibrate heat sources such as Hart dry-wells
and Micro-Baths with this software.
MET/TEMP II also lets you perform semi-automated fixed-point
calibrations. The software allows you to program soak times
in the cell before taking readings. You may even mix fixed
points with comparison points in the same calibration. Of
course, they also include fixed-point information on the new
report layout. |
| |
| If you use the 1560 Black Stack, you can simultaneously
calibrate up to 64 RTDs, 64 thermistors, 96 thermocouples or
any combination. That's a lot of sensors.
MET/TEMP II allows you to track the serial numbers, model
numbers, calibration dates, and recall dates of all test
equipment and sensors under test. Optionally, this data may
be synchronized with information in your MET/TRACK database.
MET/TEMP II also stores customer names and addresses for
printing on reports. |
|
|
|
|
  |
|
With MET/TEMP II, you make your own choices regarding
precision and throughput. When setting up tests, you specify
the required stability level at each set-point to ensure
that readings are taken only under the conditions you
require. You'll get the exact level of precision you want
based on the equipment you have and the calibration time you
set. MET/TEMP II will interface with MET/TRACK to record
calibration and maintenance history, traceability
information, and even the location of your thermometers and
heat sources. Use it with MET/TRACK and watch your
productivity take a big step up. |
| |
|
|
| Calibration reports are automatically created from your
setup data and test results. Each report conforms completely
to the requirements of ANSI/NCSL Z540-1.
It's fast, it's accurate, and it's complete. This is true
Windows software. It runs on Windows™ 9.x/ME/2000/NT/XP, and
includes a context-sensitive, online help system. Just click
the help button (or press F1) from any screen and you'll get
the information you need. When you experience the interface
of this software, you'll agree nothing could be easier. |
|
|
|
|
  |
|
The MET/TEMP II Coefficients and Tables application contains
utilities for data analysis. It calculates ITS-90
coefficients and residuals for each sensor tested. Tables
can be generated with temperature-versus-resistance,
temperature-versus-ratio, or temperature-versus-EMF data.
Each report can be generated in °C, °F, or K and in
selectable increments from 0.01 to 100. |
| |
|
|
| For PRTs, MET/TEMP II calculates coefficients for ITS-90,
IPTS-68, Callendar-Van Dusen, and polynomial functions. For
thermistors, it calculates coefficients for polynomial
functions, including Steinhart-Hart. Thermocouple
coefficients can be calculated for types B, E, J, K, N, R,
S, T, and AuPt. This software even allows you to verify that
the appropriate temperatures are used to calculate
coefficients. Need subranges in ITS-90? No problem. Want to print tables
for any temperature range and in any incremental amounts? No
problem. Need to generate formatted reports that conform to
ANSI/NCSL Z540-1? No problem. |
| |
|
|
  |
|
Data can also be exported to spreadsheets or other
statistical analysis software as comma-delimited or
tab-delimited text. MET/TEMP II does all of that and more,
but best of all it does it automatically. There's not much
you could ever want to do that this package won't do. This
is real calibration software, not merely a data acquisition
package with a fancy name! Other software packages work with
one or two instruments; they won't control the wide variety
of heat sources Hart's software does. Other software doesn't
fully automate the calibration process. They try to. They
pretend to. But they don't. Control dry-wells, baths,
readouts, and the entire calibration process. Store data on
test equipment and on sensors under test. There's absolutely
nothing even close to this software on the market. Nothing! |
|
|
|
|
|
When you've got more work to do than you can do in a 12-hour
day, and you still need some time to visit accounting to
straighten out a few things, MET/TEMP II will take care of
business for you. Go home. Spend some time with your kids.
Play a game of golf. It's your choice how you spend your
time! Please contact us about downloading a demo today! |
|