Specifications |
|
DC Voltage |
Ranges |
200 mV, 2 V, 20 V, 200 V, 1000 V |
|
Accuracy |
±(1.0 % rdg + 1 dgt) |
|
Resolution |
100 µV |
|
Input Impedance |
10 MΩ |
|
Overload Protection |
200 mV: 1000 V dc or 750 V ac rms (3 minutes)
All other ranges: 1000 V dc or 750 V ac rms |
AC Voltage True RMS
(45 Hz To 500 Hz) |
Ranges |
200 mV, 2 V, 20 V, 200 V, 750 V |
|
Accuracy |
±(1.5 % rdg + 5 dgts) |
|
Resolution |
100 µV |
|
Input Impedance |
10 MΩ |
|
Overload Protection |
200 mV: 1000 V dc or 750 V ac rms (3 minutes)
All other ranges: 1000 V dc or 750 V ac rms |
|
DC Current |
Ranges |
200 µA, 2 mA, 20 mA, 200 mA |
|
Accuracy |
±(1.5 % rdg + 1 dgt) |
|
Resolution |
0.1 µA |
|
Input Protection |
315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input |
|
Burden Voltage |
300 mV max. (1 V max. on 200 mA range) |
|
AC Current |
Ranges |
200 µA, 2 mA, 20 mA, 200 mA |
|
Accuracy |
±(2.0 % rdg + 5 dgts) |
|
Resolution |
0.1 µA |
|
Input Protection |
315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input |
|
Burden Voltage |
300 mV max. (1 V max. on 200 mA range) |
|
Resistance |
Ranges |
200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ |
|
Resolution |
100mΩ |
|
Accuracy |
200Ω, 2kΩ, 20kΩ, 200kΩ: ±(1.0 % rdg + 4
dgts)
2MΩ: ±(1.5 % rdg + 4 dgts)
20MΩ: ±(2.0 % rdg + 5 dgts) |
|
Open Circuit Voltage |
0.3 V dc typical, (3.0 V dc on 200Ω range) |
|
Overload Protection |
1000 V dc or 750 V ac rms |
|
Continuity |
Audible Indication |
75 W±25 W |
|
Response Time |
100 ms |
|
Overload Protection |
1000 V dc or 750 V ac rms |
|
Diode Test |
Test Current |
1.0 mA (approximate) |
|
Accuracy |
±(1.5 % rdg + 3 dgts) |
|
Resolution |
1 mV |
|
Open Circuit Voltage |
3.0 V dc typical |
|
Overload Protection |
1000 V dc or 750 V ac rms |
|
Battery Test |
Ranges |
1.5 V, 9 V |
|
Accuracy |
±(3.5 % rdg + 2 dgts) |
|
Resolution |
1 mV, 10 mV |
|
Loaded Current |
150 mA typical for 1.5 V range, 5 mA
typical for 9 V range |
|
Overload Protection |
1000 V dc or 750 V ac rms on 9 V range, on
VWinput
315 mA/1000 V fast blow ceramic fuse on 1.5 V range, on mA input |
|
Non-Contact Voltage
Indicator |
Sense voltage 70 V to 600 V ac; beeper