Specifications |
|
DC Voltage |
Ranges |
1000 mV, 10 V, 100 V, 1000 V |
|
Accuracy |
all ranges ±(0.1 % rdg + 5 dgt) |
|
Resolution |
100 µV |
AC Voltage True RMS
(42 Hz To 2 kHz) |
Ranges |
1000 mV, 10 V, 100 V, 750 V |
|
Accuracy |
750 V range: 45 to 1 kHz: ±(2.0 % rdg + 10 dgts)
All other ranges, 45 to 500 Hz: ±(1.2 % rdg + 10 dgts)
All other ranges, 500 to 2 kHz: ±(2.0 % rdg + 10 dgts) |
|
Resolution |
100 µV |
|
DC Current |
Ranges |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
|
Accuracy |
100 µA range: ±(0.5 % rdg + 10 dgt)
1000 uA to 400 mA ranges: ±(0.5 % rdg + 5 dgts)
10 A range: ±(1.5 % rdg + 10 dgt) |
|
Resolution |
0.01 µA |
AC Current True RMS
(45 Hz To 1 kHz) |
Ranges |
100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
|
Accuracy |
100 µA to 100 mA ranges: ±(1.5 % rdg + 10 dgts)
400 mA range: ±(2.0 % rdg + 10 dgts)
10 A range: ±(2.5 % rdg + 10 dgts) |
|
Resolution |
0.01 µA |
|
Resistance |
Ranges |
1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ |
|
Accuracy |
1000 Ω to 1000 kΩ ranges: ±(0.5 % rdg + 8 dgts)
10 MΩ range: ±(1.0 % rdg + 10 dgts)
40 MΩ range: ±(2.0 % rdg + 10 dgts) |
|
Capacitance |
Ranges |
40 nF, 400 nF, 4 µF, 40 µF, 400 µF |
|
Accuracy |
40 nF, 400 µF ranges: ±(3.0 % rdg + 10 dgts)
400 nF to 40 µF ranges: ±(3.0 % rdg + 5 dgts) |
|
Resolution |
0.01 nF |
|
Inductane |
Ranges |
4 mH, 40 mH, 400 mH, 4 H, 40 H |
|
Accuracy |
(for values of Q ≤ 7): ±(5.0 % rdg + 30 dgts) |
|
Resolution |
1 µH |
|
Frequency |
Ranges |
100 Hz, 1000 Hz, 10 kHz, 100 kHz, 1000 kHz, 10 MHz |
|
Accuracy |
all ranges: ±(0.1 % rdg + 5 dgts) |
|
Resolution |
0.01 Hz |
|
Duty Cycle |
Ranges |
0 to 90 % |
|
Accuracy |
5V logic: ±(2.0 % rdg + 20 dgts) |
|
Resolution |
0.01 % |
|
Frequency Range |
0 % to 10 %: 40 Hz to 990 kHz
10 % to 90 %: 40 Hz to 20 kHz |
|
Logic Test |
Logic Type |
TTL, CMOS |
|
Thresholds |
Logic 1 (Hi): TTL 2.8 V ±0.8 V, CMOS 4 V ±1 V
Logic 0 (Lo): TTL 0.8 V ±0.5 V, CMOS 2 V ±0.5 V |
|
Frequency Response |
20 MHz |
|
dBm |
Ranges |
-13 dBm to + 50 dBm |
|
Accuracy |
45 Hz to 5 kHz: ±(0.7 dB + 8 dgts)
5 kHz to 10 kHz: ±(2.5 dB + 8 dgts) |
|
Resolution |
0.01 dBm |
|
Continuity |
Audible Indication |
< 40 Ω |
|
Diode Test |
Test Current |
1.0 mA (approximate) |
|
Open Circuit Volts |
3.0 V dc typical |
|
Peak |
AC Volts Accuracy |
100 V, 750 V ranges: ±(3.0 % + 200 dgts)
1000 mV, 10 V ranges: unspecified |
|
AC Current |
±(3.0 % + 200 dgts)
100 µA range: unspecified |
|
Overload Protection |
AC/DC Voltage |
All ranges: 1000 V dc or 750 V ac rms |
|
AC/DC Current |
µA/mA input: F0.5 A/1000 V fast-blow ceramic (6.3 x 32 mm)
10 A input: F10 A/1000 V fast-blow ceramic (10 x 38 mm)