Specifications |
|
DC Voltage |
Ranges |
200 mV, 2 V, 20 V, 200 V, 600V |
|
Accuracy |
all ranges: ±(1 % rdg + 1 dgt) |
|
Resolution |
100 µV |
|
Input Impedance |
10 MΩ |
AC
Voltage
(45 Hz To 500 Hz) |
Ranges |
200 mV, 2 V, 20
V, 200 V, 600 V |
|
Accuracy |
all ranges:
±(1.5 % rdg + 4 dgts) |
|
Resolution |
100 µV |
|
Input Impedance |
10 MΩ |
|
DC
Current |
Ranges |
200 µA, 2 mA,
20 mA, 200 mA, 10 A |
|
Accuracy |
200 µA to 200
mA ranges: ±(1.5 % rdg + 1 dgt)
10 A range: ±(2.0 % rdg + 3 dgts) |
|
Resolution |
0.1 µA |
|
Voltage Burden
(Max) |
200 µA range: 1
mV/µA
2 mA range: 100 mV/1mA
20 mA range: 13 mV/1 mA
200 mA range: 4.6 mV/1 mA
10A range: 40 mV/1 A |
AC
Current
(45 Hz To 500 Hz) |
Ranges |
200 µA, 2 mA,
20 mA, 200 mA, 10 A |
|
Accuracy |
200 µA to 200
mA ranges: ±(2.0 % rdg + 4 dgts)
10A range: ±(2.5 % rdg + 4 dgts) |
|
Resolution |
0.1 µA |
|
Voltage Burden |
200 µA range: 1
mV/µA
2 mA range: 100 mV/1mA
20 mA range: 13 mV/1 mA
200 mA range: 4.6 mV/1 mA
10A range: 40 mV/1 A |
|
Resistance |
Ranges |
200Ω, 2kΩ,
20kΩ, 200kΩ, 2MΩ, 20MΩ |
|
Accuracy |
200Ω to 200kΩ
ranges: ±(1.0 % rdg + 4 dgts)
2MΩ range: ±(1.5 % rdg + 4 dgts)
20MΩ range: ±(2.0 % rdg + 5 dgts) |
|
Resolution |
100 m |
|
Open Circuit
Voltage |
200Ω range: 3.0
V dc
All other ranges: 0.3V dc typical |
|
Continuity |
Audible
Indication |
75Ω ± 25Ω |
|
Response Time |
100 ms |
|
Diode Test |
Test Current |
1.0 mA
(approximate) |
|
Accuracy |
± (1.5 % rdg +
3 dgts) |
|
Resolution |
0.001 V |
|
Open Circuit
Volts |
3.0 V typical |
|
Battery Test |
Ranges |
1.5 V, 9 V |
|
Accuracy |
±(3.5 % rdg + 2
dgts) |
|
Resolution |
1 mV, 10 mV |
|
Load Test
Current |
1.5 V range:
150 mA typical
9 V range: 5 mA typical |
|
Non-Contact
Voltage Detector (NCV) |
AC Volts |
70 To 600V AC |
|
Overload Protection |
AC/DC Voltage |
400 mV range:
600 V dc or 600 V ac rms 15 sec
All other ranges: 600 V dc or 600 V ac rms |
|
AC/DC Current |
uA/mA input: F
0.25 A/ 600 V Min. I.R. 30 kA (6.3 x 32 mm)
10 A inputF 10A / 600V, Min. I.R. 100 kA, (10 x 38 mm)
(10 A for 4 minutes maximum followed by a 12 minute cooling period) |
|
Resistance |
600 V dc or 600
V rms |
|
Continuity |
600 V dc or 600
V ac rms |
|
Diode Test |
600 V dc or 600
V ac rms |
|
Battery Test |
600 V dc or 600
V ac rms |