Test Equipment Depot - 800.517.8431

Test Equipment Catalog Specials  Repair Surplus Ordering/Contact Info

ACR Systems
ACR Catalog | ACR Price List
 

<< ACR Catalog

ACR Systems SmartReader Plus Data loggers

  • Multiple Channels
  • Monitor a variety of parameters
    • Temperature
    • Relative Humidity
    • Current
    • Voltage
    • Pressure
    • Process Signals
    • Pulse
  • 8-bit or 12-bit resolutions (on specific models)
  • 10 year Battery Life
  • 32KB, 128KB, or 1.5MB Memory capably (on specific models)
  • Remote access via modem or Ethernet connections
  • Fast Sample Rates (up to 25 Samples)
  • User configurable
  • Network capable (connect up to 10 data loggers)
  • Alarm Dial-out


ACR SmartReader Plus
Data loggers Shown

 
ACR SmartReader Plus are multi-channel, user configurable data loggers that feature 32K, 128K or 1.5MB memory. SmartReader Plus loggers are accessible remotely by modem; multiple loggers can also be linked to form a network.

Each r Plus is capable of handling a wide range of specific needs as well as general data logs, and can be coupled with specialized probes, furthering it's adaptabilities to the user's needs. Furthermore the probes are cross-compatible with the SmartReader series, making the SmartReader Plus a powerful, affordable addition to your instruments.
 
SmartReader Data Loggers Plus
Model # of Channels Memory Measurement Types Measurement Range (with probes)
SmartReader Plus 1 2 32KB
128KB
1.5MB
Temperature (w/ Thermistors)/Resistance/Switch Status, Ambient Temperature -60 to 255°C (-76 to 491°F)
SmartReader Plus 2 4 128KB Temperature, Relative Humidity (internal), Ambient Temperature, Relative Humidity(External) -40 to 70°C (-40 to 158°F), 0 to 95% Relative Humidity
Conservation Logger 4 128KB Internal temperature channel, Internal relative humidity channel, 0-5 Volt DC inputs (2, optional sensors) 0-5V (2x)
SmartReader Plus 3 8 32KB
128KB
1.5MB
Ambient Temperature, AC Current (4, w/ AC Current Probes), AC Voltage (3, w/ 1 or 3 Phase Voltage Transducers) 5-500A
(Up to 3000 Amps w/ Current Transformer), 0-5V or 120VAC, 480VAC
SmartReader Plus 4 4 32KB
128KB
Ambient Temperature, Pressure, Relative Humidity, Temperature/Resistance/Switch Status 0-5, 30, 100  & 150 PSI
SmartReader Plus 4 LPD 2 32KB Ambient Temperature, Low Pressure +/-0.5", 1", 2",
5", 10" WC
SmartReader Plus 5 3 32KB
128KB
Ambient Temperature/Cold Junction Compensation), Thermocouple Temperature (2) J, K, S, T, Thermocouple Ranges
SmartReader Plus 6 8 32KB
128KB
1.5MB
Ambient Temperature, Thermocouple Temperature (7) J, K, S, T, Thermocouple Ranges
SmartReader Plus 7 8 32KB
128KB
1.5MB
Ambient Temperature, Analog Inputs (7) 0 - 2.5V, 0 - 5V, 0 - 10V, 4 - 20mA, 0 - 200mV
SmartReader Plus 8 8 32KB
128KB
1.5MB
Ambient Temperature, Temperature (7, With Thermistors)/Resistance/Switch Status -60 to 255°C (-76 to 491°F)
SmartReaderPlus 9 2 32KB
128KB
Externally Generated Pulse signals/Dry Switch Contact Closures (2) 4095 Pulse/Second Period
SmartReader Plus 10 4 128KB Ambient Temperature, Temperature w/ RTD Probes (3) -230 to 300°C (-385 to 572°F)
 

ACR Catalog   |   ACR Price List

$20.00 Minimum on Total Order

Home Page | Test Equipment Catalog | Specials | Repair
We Buy Surplus | Ordering/Contact Info
____________________________________________________________

99 Washington Street, Melrose, MA 02176
781.665.1400 | 800.517.8431 | Fax: 781.665.0780 | Email:

Copyright © Fotronic Corporation All Rights Reserved