ACR Systems Humidity Dataloggers
<<
ACR Systems Air Quality Dataloggers |
ACR IAQ Logger
Temperature, Humidity and C02
Data Logging Solution
|
- Monitor and record indoor air quality
- Temperature
- Relative Humidity
- Carbon Dioxide
- Real time display
- Option to monitor resistance, switch status or 2nd
temperature and RH measurement
|
 
ACR IAQ-100 System Shown
|
|
|
|
The IAQ Logger, when combined with the GE Telaire 7001 Handheld CO2
Monitor, records the three leading indicators of indoor air
quality: (1) temperature, (2) relative humidity, and (3) carbon
dioxide. This IAQ solution is ideal for those applications
requiring long-term, close monitoring and recording.
Quickly and easily verify the temperature and CO2 on the
Telaire's large, easy-to-read display. |
|
|
|
IAQ Logger Specifications |
|
No. of Channels |
| Five |
|
- One for Ambient temperature
- One for Relative humidity
- One for Carbon dioxide
- Two for temperature and/or RH (with ACR thermistor
probes)
|
|
|
Clock Accuracy |
+/- 2 seconds per day |
|
Memory Size |
32 KB (32,767 readings) |
|
Sampling Methods |
1. Continuous (First-in, First-out)
2. Stop when full (Fill then stop) |
|
Sampling Rates |
User selectable rates from 8 seconds to once every
5 days |
|
Resolution |
8-bit |
|
Power Source |
Battery |
3.6 volt Lithium, |
|
Power Consumptions |
5 years under normal use (factory
replaceable) |
|
Battery Life |
10 Years under normal use |
|
General Specifications |
Size |
107 mm x 74 mm x 22 mm (4.2" x 2.9" x 0.9") |
| Case Material |
Noryl plastic |
|
Weight |
110g (3.75oz) |
| Mounting |
Magnetic backing and locking eyelet |
|
|
PC Requirements |
|
Processor/Operating System |
IBM PC or 100% compatible running Windows
3.1, '95, '98, 2000, ME, NET, XP |
|
Available Hard drive space |
At Least 2MB |
|
Memory |
At Least 2MB |
|
Communication Ports |
1 Free Serial Port |
|
|
Software |
|
Basic Software: TrendReader 2 System
Requirements (Required for Standard use) |
|
Processor |
Pentium II-350MHz or Faster |
|
Operating System |
Windows 2000 SP4, XP SP2 |
|
Available Hard drive space |
At Least 250 MB of Hard disk space |
|
Memory |
128 mb of Ram (256 MB Recommended) |
|
Communication Ports |
USB or Serial Port, dependant on
interface cable |
|
Internet Browser |
Internet Explorer 6 or higher |
|
Screen resolution |
1024 x 768 or higher |
|
Additional Equipment |
Mouse or other pointing device |
|
More info |
More info
on the TrendReader Standard 2>> |
|
|
Telaire 7001
Specifications |
|
Size |
107 mm x 80 mm x 40 mm (6.7" x 3.1" x
1.6") |
|
Case Material |
ABS plastic |
|
Mounting |
Pull-out Stand |
|
Operating Limits |
0 to 50°C (32 to 122°F) and 0 to 95% RH (non-condensing) |
|
Power Supply |
6 VDC from external AC/DC adapter (included) or
4 AA batteries (not included) |
|
Additional
info |
More info